Name Parameter Remarks
Rated voltage (V) DC12V
The maximum instantaneous working current is 2.5A ± 15% without any abnormal peaks, or the peak is less than 3A
Minimum unlocking voltage 9V
Anti roof door force 12V/10kg
Resistance 6 Ω
Maximum instantaneous working power ≤ 24W
The maximum load-bearing force of the lock buckle is ≥ 1200N, and the lock cannot be opened
Load unlocking test ≥ 100N, can be unlocked when powered on
Opening door elasticity ≥ 1.0kg ± 15%
The maximum bending resistance (elastic deformation) of the lock buckle is ≥ 80N
Lock shell material SCPP galvanized
Wire SM-6A female connector. The strength between the rubber shells is 2kg, and there is no detachment or breakage within 1 minute
Damage and poor conductivity
Weight ≈ 210 grams for reference
Working temperature -40 ℃ to+80 ℃
Storage temperature -40 ℃ to+80 ℃
Neutral salt spray test ≥ 48 hours
Lock shell size (WxHxD) 76 * 70 * 14 mm for reference
The power on time should not exceed 1 second for a single continuous power on, and unlocking should be done continuously at intervals of 10 seconds without damage;
Normal unlocking and power on for 300ms
The lifespan testing equipment has been tested 50000 times without any damage